Overview

The band switch is a rotary selector switch, which is successfully used in the control box of KZH-134A, KZH-319 and so on. Compared with the pull trigger switch,press on switch, the band switch can output more circuit signals at the same time with longer service life. Shanghai Aviation Electrical Appliance Co., Ltd. is a pioneer in energy storage, fast moving technology, press release design technology and interface design technology.

DK-14A
Function

The basic function of rotary switch is to trun the main shaft to turn on the circuit accurately with quick hop function. When the switch is rotated from the left end along the clockwise, it can be transited to three positions smoothly. When the switch is rotated from the right end along the counterclockwise, it can be transited to the middle position smoothly. Then when pressed the spindle by a certain distance, it can be successfully converted to the left end position.

Tech Spec
  • Input rated voltage:27VDC
  • Inductive load current:0.1A
  • contact resistance:no more than 20mΩ
  • Lifetime: 5000 working cycles
  • Insulation dielectric strength:500V/50Hz, duration 1min,there should be no breakdown or flicker
  • Working temperature:-55℃~+70℃, work continuously for 1h
  • Resistive load current:1.5A
  • Time constant:τ≤0.015s
  • insulation resistance:no less than 20MΩ
  • Storage temperature:-55℃~+70℃
DK-11-4×3
Function

The basic function of rotary switch is to trun the main shaft to turn on the circuit accurately without quick hop function. When the switch is rotated from the left end along the clockwise, it can be transited to three positions smoothly. When the switch is rotated from the right end along the counterclockwise, it can be transited to the middle position smoothly. Then when pressed the spindle by a certain distance, it can be successfully converted to the left end position.

Tech Spec
  • Input rated voltage:27VDC
  • Inductive load current:0.1A
  • contact resistance:no more than 20mΩ
  • Lifetime: 5000 working cycles
  • Power frequency is 50Hz,The effective value of the test voltage in cold or hot state is 500V, Voltage duration is 1min, No breakdown or flicker
  • Working temperature:-55℃~+70℃, work continuously for 1h
  • Resistive load current:1.5A
  • Time constant:τ≤0.015s
  • insulation resistance:no less than 20MΩ
  • Storage temperature:-55℃~+70℃
?
Products & Solutions
Lighting Solutions
CPAs & DCS Solution
Warning Solutions
Secondary PDM Solutions
Speech R & S Solutions
Core Electric Apparatus
Automotive Components
Civil Aircraft Maintenance
Application Fields
Aviation
Non-aviation Defense
Civilian
About Us
Company History
Management Team
Enterprise Culture
Enterprise Strategy
Organization
News
Contact Us
Tel:021-61867331(9:00-17:00)
WeChat Official Accounts:

Contact Us:Tel:021-61867331(9:00-17:00)

Copyright ? 2016 All Rights Reserved  AVIC SAE  滬ICP備07014711號(hào)-3 滬公網(wǎng)安備31011202001332號(hào)

中文 English